(C) Copyright.	Andrew Dainis
=============================================================================

The C3D data file format was developed by Andrew Dainis in 1987 as
a convenient and efficient means for storing 3D coordinate and analog
data, with all associated parameters, for a single measurement trial.

One design goal of the C3D file format was to provide the user a means
to easily examine, and if necessary modify, any parameter contained
in the file. This goal was achieved by providing the user with a program
(PRM) which interactively allows access to the parameters stored internaly
in binary format.
=============================================================================

			    TABLE OF CONTENTS


1.	Parameter Manipulation Program PRM
2.	C3D Data File Format
3.	Parameter Access From Programs

=============================================================================


1.  PARAMETER MANIPULATION PROGRAM PRM

1.1  INTRODUCTION 

     The PRM program provides the user a means of accessing the parameters in
C3D and other ADTECH parameter files. It operates interactively through a few
simple commands and provides output to terminal screen, printer, or file. The
program allows the user to create, examine, change, and delete parameters in any
file that contains data in the ADTECH parameter format, and acts as a friendly
interface between the user and the parameters.


1.2  PARAMETER FORMAT 

     This section describes the format of the parameters as displayed by the
PRM program. Internally to a file the parameters are stored in binary format and
may be directly accessed using the techniques described in sections 2. and 3.

     Each parameter is identified by a name, and has a data type. A parameter
also has dimensions which describe how many pieces or elements of data it can
hold, and optionally, a description. Additionally each parameter belongs to a
parameter group having a group name and a group description. In listings and
commands the group name and parameter name are separated by a colon (:). By a
suitable choice of group and parameter names, and through the descriptions, it
is possible to make the parameter functions largely self-explanatory. The
ability to group parameters enables parameters pertaining to different functions
to be included in the same file without risk of confusion. 

     A parameter or group name may consist of any number of characters made up
from the letters A through Z, the numerals 0 through 9, and the underscore
character  _ . The name should not start with a numeral or the underscore
character. When a name is interpreted only the first six characters are used.
Hence all group names and all names within a group should show at least one
difference in the first six characters. The same names may be used for two
parameters if they occur in different groups. 

     A parameter's type determines the type of data that may be stored in it.
Four parameter types are used; integer, real, character, and byte. These data
types correspond to the conventional meaning of the terms in computer
programming. An integer is a 16-bit signed number between -32768 and +32767, a
real number is one containing a decimal point or written in scientific
exponential representation, a character is a literal symbol such as a letter
entered from the keyboard, and a byte data location can contain a 8-bit signed
integer in the range -128 to +127. 

     The dimensions of a parameter define how many elements of the appropriate
type may be stored in that parameter. The use of the term dimensions also
follows normal programming conventions. If a parameter has no dimensions, then
it may only hold one value of its data type. If it has one dimension it is
presented in the form such as PARM(4) where the  4  indicates that the parameter
called PARM is capable of holding four values. Examples of two- and three-
dimensional parameter arrays are PARMA(4,5) and PARMB(3,5,7). The first example
has 4 x 5 = 20 elements, and the second parameter holds 3 x 5 x 7 = 105 entries.
The content of any parameter element may be selectively examined and modified
by use of the PRM program.

     The description part of a group or parameter definition simply provides
information as to the function of the particular group or parameter, and is
included for informational purposes only.


1.3  RUNNING THE PROGRAM 

1.3.1  Starting the PRM Program 

     The Parameter Manipulation Program is started by entering 
               
               PRM  <file name> 

from the keyboard in response to the operating system prompt. The screen will
clear, the program title will be displayed, and the requested file will be
opened. If no file name is provided, the program will request the input of a
file name.


1.3.2  Accessing the Parameters

     If the named file is found, it is opened and the program first tests to
determine that the file does contain parameter data. If the format is valid, the
data are read into memory and become available for manipulation. If the file
does not contain parameter data a message to that effect is output to the
terminal screen and the user is prompted for another file name. If the named
file cannot be opened for any reason, a new file is opened in preparation for
creating a new set of parameters and a  new file  message is displayed on the
terminal screen. The user then may proceed to create parameter groups and
parameters as described in the remainder of this chapter. Once the program is
ready to accept parameter manipulation commands, the prompt symbol ? will be
displayed. If a mistake was made in entering the file name and the user does not
wish to create a new file, the abort command AB(ort) should be entered in
response to the ? prompt. In this circumstance the program will ask for another
file name.

     When an existing file is opened, the program first lists the existing
parameter groups before displaying the ? prompt.


1.3.3  Terminating the Program 

     Either of the commands ABort or EXit will terminate the PRM program. The
ABort command will cause the program to exit without making any changes to the
input parameter file, whereas the EXit command will cause the input file to be
updated with the changes entered during this session. 


1.4  COMMAND DESCRIPTION 

     The PRM program responds to eight commands: CREATE, DELETE, LIST,
PRINT, WRITE, CHANGE, ABORT, and EXIT. All commands except CREATE may
be abbreviated to their first letter. The shortest abbreviation allowed for
CREATE is CR. The CREATE and DELETE commands will be described first.
However, the user will very rarely need to use these two commands since the
modification of existing parameter files, or of copies of existing files,
provides a more efficient technique for obtaining new files. The creation of a
new parameter file must be done very carefully because errors in parameter names
or dimensions will cause programs to reject the parameter data. Occasionally the
CREATE and DELETE facilities may be useful for changing the dimensions or
description of a parameter, or replacing an incorrectly created parameter.

     In the following command descriptions, di refers to the ith dimension of
a parameter (for instance, the 7 in CAM_CHAN (7) ).


1.4.1  Create (CR) 

1.4.1.1  Group

     To create a new parameter group, the command is

          CReate group_name:/description

     The group called group_name is created, and with it is associated a
description. If a group is being created, the ':' must be specified. Also, the
slash character '/' must be used to separate the description from the rest of
the command. 


1.4.1.2  Parameter

     To create a parameter within an existing group, use the command

CReate {group_name:}parameter {(d1, d2,...)},type/description


     If a group name is not placed in front of a parameter name, the parameter
will be created in the default group. The default group is the one whose name
was last specified in any command. If a group name is included before the
parameter name then the parameter is created in the specified group. 

     A parameter may have up to seven dimensions, but normally none, one, or
two are used. If no dimension is defined then that parameter can only hold one
element. The parameter type must be specified as a single character from the
list of four; I, R, C, and B where I denotes Integer, R denotes Real, C
denotes Character, and B denotes Byte. The slash / must precede the description
part of the definition. 

     When a parameter is created, it is filled with default values. For
numerical parameters (those of type real, integer or byte) the default value is
zero. For the character type of parameter the default entry in all locations is
the space ' ' character. Once a parameter or group is created, its name,
dimensions, or description may only be changed by deletion and re-creation. 

     There are no restrictions on the length of group or parameter names, which
must be made up from the letters A - Z, the numerals 0 - 9, and the underscore
character  _ . A name should not start with a numeral or  _ . Only the first six
characters of a name are referenced when a name is interpreted. Therefore no two
names of parameters in the same group should be identical in all first six
characters. Parameters may only have the same names if they belong to different
groups.


1.4.2  Delete (D) 

     Groups and parameters may be deleted. A group may be deleted only after
all parameters within it have been deleted. A parameter may be deleted if it is
not locked by the program that created it. A locked parameter (identified by and
asterisk (*) in front of its description) may also not be modified by the CHANGE
command. The delete command has the format

          Delete group_name:

               or

          Delete group_name:parameter_name

     Note that a group name must always be used when a parameter is being
deleted. Also, any parameter or group name may be abbreviated, even down to one
letter. However, if the abbreviation can refer to more than one name, action may
be taken on the wrong parameter.


1.4.3  List (L), Write (W), or Print (P) 

     The only difference between these commands is the output device to which
the information is sent. The List command results in output to the terminal from
which the command was entered, the Write command writes the output to a file
named LISTPAR.DAT, and the Print command additionally sends the LISTPAR.DAT file
to the system printer. Note that data are written to the output file until
either the EXit or ABort command is given, at which point the file is closed
(and sent to the printer if the Print command was used). 


1.4.3.1  Groups

     A listing of all groups may be obtained by the command

          L :

where the : symbolically denotes groups. The space between the command and the
colon is required. The parameter names, dimensions and descriptions contained
in any group may be listed by the command

          L group_name:

and an L without any group name will list all of the parameter names in the
current default group. It should be noted that any time a group name is used,
that group becomes the current default group. Also, when a group is listed the
content of any parameter that has a single element is also automatically listed.


1.4.3.2  Parameters

     This output commands has the general syntax:

          List {group _name:}parameter_name {(d1 {, d2,..})}

If the group name is omitted, then the current default group name is used. A
parameter name must be specified, and the dimensions are optional. Abbreviations
for group and parameter file names may be used. If no dimensions are specified,
the values of all elements of the parameter are listed. By use of entries within
the dimension parentheses, any subset of elements of the parameter may be
listed. As an example, consider a parameter that was created with the command 

          CR COORD(3,20),R/Reference point coordinates

The organization of this parameter may be thought of as consisting of 60 storage
locations arranged in an array that has three rows and 20 columns. Each location
can store a real (floating point) number. The command 

          L COORD

will cause the PRM program to list all values in COORD starting with the value
stored in location (1,1), followed by (2,1), (3,1), (1,2), (2,2), (3,2),
(1,3),.... , (3,19), (1,20), (2,20), (3,20), i.e., the first dimension is varied
most rapidly, followed by the second dimension, and so on. The command

          L CO(2,15)

will list the value stored in the second row and the 15th column. If a dimension
is omitted, all the elements for that dimension will be listed, i.e., the
command 

          L COORD(,15)

will list the elements (1,15), (2,15), and (3,15), whereas the command

          L COORD(3,) 

will display the values in (3,1), (3,2),...., (3,20). The command L COORD(,)
is equivalent to L COORD . The above example illustrates how program PRM
provides a simple and flexible facility for selecting parameter data for display
or modification. 


1.4.4  Change (C) 

1.4.4.1  Groups

     The Change command may be applied to an entire group as in 

          Change group_name:

to have the program prompt for the modification of all single element parameters
contained in the group.


1.4.4.2  Parameters

     In its most general form the change command has the format

          Change {group_name:}parameter_name {(d1, {d2, ...})}

     If a group name is not given, the current default group name is assumed.
The rules for accessing the elements of a dimensioned parameter are the same as
those for the LIST command, i.e., all, some, or one of the elements of a
parameter may be selected for modification. After a change command is entered,
each element is listed on the terminal with its current value. The user is then
prompted for the entry of a new value. Pressing just the <ENTER> key leaves
the value in that particular element unchanged. If the user wishes to exit from
the change mode without completing the list specified in the change command,
then the PRM prompt symbol ? should be entered. 

     Some parameters are locked by their creating programs in order to protect
the data from modifications which may cause succeeding programs to function
incorrectly. A locked parameter can be recognized by an asterisk preceding its
description, and any attempt to change or delete it results in a message stating
that it is locked. 

     The first dimension of a parameter which has a character type determines
how long the lines are for entering characters. For example, a character
parameter with dimensions (30,5) holds five lines, with each line having room
for 30 characters. A command to change or list the third line would specify the
dimensions (,3) . Actually for character parameters, the first dimension may be
omitted altogether, and the dimension may be specified as just (3). 


NOTE: To clear a character line of any text, enter a single exclamation mark
in response to the prompt for input for that line.


=============================================================================

2.  C3D DATA FILE FORMAT

2.1  FILE STRUCTURE

    The coordinate (and analog) data in .C3D files are written in 16-bit
integer (INTEGER*2) format, or optionally floating point (REAL*4) format,
consisting of records that are 512 bytes long. The files have three sections.
The first section consists of just one header record and contains a few
parameters as described in Section 2.2. The second section starts at record
number 2 and contains parameters in ADTECH format. This section is variable in
length but is typically about 10 records long. The rest of the file contains
the 3D point coordinate data, and analog data if analog data were available
when the .C3D file was created. Standard format of coordinate and analog data
is in the integer format. However, the facility for the data to be written
in REAL*4 format is also available for the storing of filtered data where the
integer form may not provide sufficient precision.
 
 
2.2  HEADER RECORD

    Although all parameters of interest are contained in the parameter
section, a few essential parameters necessary for accessing the data in the
file are repeated in the header record in simple form. The parameters in this
record are useful if one does not wish to use the parameter subroutines
required to access the quantities written in parameter format. The ADTECH
parameter format allows for very convenient interactive user access, but is
more complex from the programming aspect. The first few words of the header
record are utilized to store the abbreviated parameter data, and the rest of
the header record contains zeros unless time event data have been written to
the data file. The parameter values stored in the header record are as listed
in Table 2.1. The 16-bit words hold integer values unless otherwise noted.






  WORD		       CONTENTS
-----------------------------------------------------------------------------

    1		 Byte 1:  number of 1st parameter record
		 Byte 2:  must contain	80(decimal)
 
    2		 Number of 3D points
 
    3		 Number of analog channels for which data is stored
 
    4		 Number of first video frame in .C3D file
 
    5		 Number of last video frame in .C3D file
 
    6		 Maximum interpolation gap allowed (in frames)
 
   7,8		 (REAL*4) Scale factor for converting integer 3D data to
		 reference system units. If negative, 3D data is already in
		 REAL*4 format.

    9		 Starting record number for 3D point and analog data
 
   10		 Number of analog frames / video frame
 
 11,12		 (REAL*4) Video frame rate (Hz)
 
 13-149 	 Currently not used
 
  150		 12345(decimal)	keyword to identify presence of event data

  151		 Number of defined time events -- maximum of 18
 
  152		 Not used
 
153-188 	 (REAL*4) Event times (in seconds) -- maximum of 18
 
189-198 	 (BYTE*1) Event display switches (0=ON, 1=OFF)

199-234 	 Event labels. 4 characters for each event.
 
-----------------------------------------------------------------------------

	  Table 2.1 -- Contents of first record of .C3D file.
                                  
 
 
 
2.3  PARAMETER RECORDS

    The parameter section is written in ADTECH parameter format which
allows the user to interactively access the parameters with the program PRM.
Programmers may access the parameters through the  FORTRAN library PRMLIB
or write programs to access the parameter data directly. Chapter 3 provides
instructions for calling the subroutines in the PRMLIB library, and the rest
of this section describes in detail the ADTECH parameter format for those
that want to access the parameters the hard way.

    The first two bytes of the first parameter record are either not used,
or form the  first two bytes of the file. If they are the first two bytes of
the file (not the case for C3D files), then byte 1 contains the number of the
first parameter record, and byte 2 contains 80 (decimal).

    Byte 3 of the first parameter record contains the number of parameter
records, and byte 4 contains 85(decimal) + processor_type. Processor_type may
have the value 1, 2, or 3, and is defined in Section 3.1. The actual parameter
data start at byte 5 of the first parameter record.

    Within the parameter records, the data belonging to groups and
parameters are stored in no particular order, and are located by searching
through the total data block. The storage unit is the byte.


Group data are stored in the following format:
-------------------------------------------------------------------------------
 Byte 1             Number (n) of characters in group name
 
 Byte 2             Group ID number (negative)
 
 Bytes  3 --> 3 + n - 1       Group name
 
 Bytes	3 + n , 3 + n + 1    (2-byte integer) offset in bytes pointing to
			     start of next group/parameter

 Byte  3 + n + 2	     Number (m) of characters in group description
 
 Bytes	3 + n + 3 -->  3 + n + 3 + m - 1     Group description
 


 Parameter data are stored in the following format:
-------------------------------------------------------------------------------
 Byte  1            Number (n) of characters in parameter name
 
 Byte  2            Group number (positive) to which parameter belongs
 
 Bytes	3 -->  3 + n + 1     Parameter name
 
 Bytes	3 + n , 3 + n + 1    (2-byte integer) offset in bytes pointing to
			     start of next group/parameter
 
 Byte  3 + n + 2	     Length in bytes of each data element
			       -1 for Character
				1 for Byte
				2 for Integer*2
				4 for Real*4
 
 Byte  3 + n + 3         Number (d) of dimensions of the parameter (max. = 7)
			 d = 0 if the parameter is undimensioned.
 
 Bytes  3 + n + 4  -->  3 + n + 4 + d - 1    Parameter dimensions
 
 Byte  3 + n + 4 + d  -->  3 + n + 4 + d + t - 1
			   The parameter data. t = product of all dimensions
			   and element length
     
 Byte  3 + n + 4 + d + t   Number (m) of characters in description
 
 Bytes  3 + n + 4 + d + t + 1  -->  3 + n + 4 + d + t + 1 + m - 1   Parameter
								    description


    The PRM program responds to the command SH, which will dump all
parameter records in byte format, and their ASCII equivalent, to the screen.





2.4  DATA RECORDS

    The 3D coordinate and analog data are written frame-sequentially
starting at the beginning of the first data record. The data are packed into
records such that frames may cross record boundaries. The 3D coordinate data
are normally stored in 16-bit integer format and must be multiplied by the
POINT:SCALE factor to generate values expressed in the external (reference
coordinate system) measurement units. If the data is stored in floating point
format (REAL*4), then the scale factor has already been applied and it is set
to be negative.

    Each 3D point is described by four words. If the data is stored in
integer form, these 16-bit words contain the following:


    WORD			       CONTENTS
-----------------------------------------------------------------------------
                                   
      1 		  X-coordinate of point / scale factor
 
      2			  Y-coordinate of point / scale factor
 
      3 		  Z-coordinate of point / scale factor
 
      4 		  Byte 1: cameras that measured marker (1 bit for each
			      camera)
			  Byte 2: average residual for point measurement
			      / scale factor
-----------------------------------------------------------------------------
                 Table 2.2 -- 3D point data contents.
                                    

	The video data for frame one are stored first, followed by one or more
analog "frames" if analog data are present. If the analog data rate was the
same as the video frame rate then only one analog frame will follow each video
frame. If analog rate was twice the video rate, then two analog frames will
follow the video frame, etc. Both the video and analog data will always be in
the same format, .i.e., INTEGER*2 or REAL*4.


 NOTES:
 
    In Byte 1 of Word 4, bits are set corresponding to which cameras
      contributed to the point's measurement. Bit 0 refers to the first
      camera, bit 1 the second, etc. 
 
    If a point was invalid in a frame (not observed by at least two
      cameras), its 4th word will be set to -1, and the X, Y, and Z
      coordinates will be set to zero. For points that were interpolated,
      the residual is set identically to zero.
  
    In an integer file the coordinates and residuals are recorded in
      internal units, and must be multiplied by the scaling factor in
      POINT:SCALE to obtain reference coordinate system units.
 
    The analog data are stored in the same order as in the raw data file,
      i.e., if the analog frame rate was higher than the video frame rate,
      the order through the channels is repeated as many times as is
      appropriate. The first word after the end of the analog data is the X-
      coordinate of the first point in the next frame. 
 
    If the data is stored in floating point format, the X, Y, and Z
      coordinates have already been multiplied by the scale factor. The 4th
      word is the normal 4th word integer value stored as a floating point
      number. To extract its data, it should be converted to integer, divided
      into high and low bytes, and the low byte must be multiplied by the
      scale factor to obtain the correct residual value.

===============================================================================

3.  PARAMETER ACCESS FROM PROGRAMS

3.1  PARAMETERS IN FILES
     
	The location of parameter records in any file is specified as follows:
 
1.  Byte 1 of the first record of the file must contain the record number
     of the first parameter record in the file.

2.  Byte 2 of the first record of the file must contain 80(decimal).

3.  Byte 3 of the first parameter record must contain the number of
     parameter records to  follow.

4.  Byte 4 of the first parameter record must contain	83(decimal) + data_type.

Data_type is an integer having a value 1, 2, or 3 and designates the computer
system type  the file was created on, or is formatted for. Recognized values
are;

	      1  =  PC-DOS
	      2  =  DEC  (VAX , PDP-11)
	      3  =  MIPS processor (SGI , SUN)

The library routine GPREC checks for the above four conditions when parameter
data is read from a file, and the parameter output subroutine OUTPT ensures
that the four bytes described above are written to the output file.



3.2  CALLING PROGRAM REQUIREMENTS

    The data stored in ADTECH parameter format may be accessed from user
programs by the use of calls to subroutines and functions contained in the
parameter library PRMLIB. The library is provided in Microsoft 16-bit FORTRAN
format.
 
     The routines operate on the entire parameter data set which must be
first read into memory by the function GPREC. Once in memory, parameters may
be created, deleted, read, or modified. At conclusion, the entire parameter
set may be output to a file by the subroutine OUTPT.

    In order to use the library routines, the calling program or subprogram
must contain the following statements:

    PARAMETER (LMSIZE=5120)

    INTEGER*1 LM(LMSIZE)

    INTEGER*2 RECL,LBOT,LTOP
    COMMON /PAR1/LBOT,RECL

    RECL=512
    LTOP=LMSIZE

    The array LM must be large enough to store the entire parameter set,
i.e. LMSIZE must be at least 512 * number of parameter records. An LMSIZE of
5120 bytes is adequate for most .C3D files.

     Before the library routines can be used, the file containing the
parameter data must be opened. In this chapter the variable LUN will be used
for the data file logical unit number, and LCT will be used for the terminal
output logical unit number. Normally they would be assigned in the calling
program as for example in

    LUN=2
    LCT=5


In the following both LUN and LCT can be constants or variables.

    The command to open the file will be similar to the following;

    OPEN (UNIT=LUN,FILE='file_name',STATUS='OLD',
   *  ACCESS='DIRECT',RECL=512,ERR=800)


If the file is opened successfully, the routines described in the next
section can then be used to access the parameters.



3.3  SUBROUTINES AND FUNCTIONS

3.3.1  Read in all parameters

FUNCTION GPREC (LUN,LM,LTOP,ISTREC,INTYP)

    This function reads in all parameter data into the array LM and
     converts it to the current processor type (see Section 3.1).  GPREC
     must be declared as an INTEGER*2 function and it returns:

    GPREC   =  0	if the read is successful
	      -1	if there was a file read error
	      -2	if parameter records were not found in the file
	      -3	if LTOP was exceeded (LM was too small)

    ISTREC is output, and returns the record number in the file where the
     parameters started. INTYP is also output and contains either 1, 2, or
     3 specifying which processor type the file was formatted for.  After
     the data is read in the input file may be closed.


3.3.2  Write parameters to file

SUBROUTINE OUTPT (LUN,LM,ISTREC,IRLAST,OUTYP)

    Writes the full parameter set to logical unit LUN. The file must have
     previously been opened as a direct access file. ISTREC is input and
     specifies the record number where the first parameter record is to be
     written. This value will be stored in the first byte of the data file
     as a pointer to the start of the parameter data. IRLAST returns the
     record number of the last parameter record in the file, i.e., the
     number of parameter records written is given by IRLAST - ISTREC + 1.
     OUTYP is input to the routine and specifies in what processor format
     type the parameters are to be written. This parameter may have the
     values 1, 2, or 3 as described in Section 3.1.


3.3.3  Create a parameter group

SUBROUTINE DEFG (GNAME,DESCR,IFG,LM,LTOP)

    Creates a parameter group whose name is in GNAME. GNAME may be a
     character string, or an INTEGER*1 or LOGICAL*1 array terminated with a
     null byte. Similarly, a group description is specified as a character
     string or byte array in DESCR. The variable IFG is output and contains
     the (negative) internal group ID number assigned to this group. An
     example of a call might be

    CALL DEFG ('POINT','Point parameters',IFG,LM,LTOP)

     Note that in Microsoft FORTRAN, the 'C' character must be appended to
      literal strings, as in 'POINT'C .
 
 
 
 3.3.4  Create a parameter
 
 SUBROUTINE DEFP (PNAME,TYP,GNAME,DESCR,LM,LTOP)
 
     A parameter with the name contained in PNAME is created in an existing
      group having the name GNAME.  TYP is one of the single character
      literals 'I','R','B', or 'C' specifying that the  parameter is of type
      Integer (INTEGER*2), Real (REAL*4), Byte (INTEGER*1 or LOGICAL*1), or
      Character, and DESCR contains a description string. PNAME may specify
      dimensions which are interpreted as described in Chapter 8 of the
      User's Manual. Example:
 
     CALL DEFP ('NN(3,4)','I','GRP1',
    *                 'Descriptive text',LM,LTOP)
 
     This call would create a parameter named NN of type integer, and having
      dimensions (3,4). If it is desired to use a variable for one or more of
      the dimensions, then the subroutine ENCN described in Section 3.3.8
      must first be used to encode the dimensions into the parameter name
      string.
 
 
 3.3.5  Delete a Group
 
 SUBROUTINE DELG (GNAME,LM,LTOP)
 
     Deletes the group entry for GNAME. All the parameters in the group must
      have been first deleted. e.g.,
 
          CALL DELG ('GRP1',LM,LTOP)
 
 
 
 3.3.6  Delete a Parameter
 
 SUBROUTINE DELP (GNAME,PNAME,LM,LTOP)  
 
     Deletes the parameter named PNAME in the group GNAME and reclaims
      space, e.g., 
 
          CALL DELP ('GRP1','NN',LM,LTOP)
 
 
 
 3.3.7  Read or write parameters
 
 SUBROUTINE PRPAR (LCT,PNAME,GNAME,IFN,ADDR,LM,LTOP,MAXD) 
 
 This subroutine performs the following functions depending on the input value
 of IFN.
 
 
 IFN		       FUNCTION
---------------------------------------------------------------------------
  0  The contents of the parameter specified in PNAME are listed to unit
      LCT. 
 
  1  Causes a prompt for the interactive modification of the parameter(s)
      PNAME via logical unit LCT. 
 
  2  The parameter values specified by PNAME are extracted from the
      parameter set and stored in the variable ADDR. MAXD specifies in bytes
      the maximum amount of data that is allowed to be read into ADDR (i.e.,
      the size of ADDR). If the data specified in PNAME is larger than MAXD,
      then no action is taken and MAXD is returned as -1. Otherwise MAXD is
      returned as the number of bytes actually read in. If the parameter
      cannot be found MAXD is returned as zero. In an error condition a
      message is written to unit LCT. 
 
  3  The data starting at variable ADDR is stored in the parameter PNAME.
      MAXD should be set to the number of bytes expected to be stored. MAXD
      is returned as 0 if there was room for all data, and returned as the
      number of bytes actually stored if there was not enough room. If the
      parameter was not found MAXD is returned as -1. 
 
 -3  Data is stored as for IFN = 3, but the parameter is locked to prevent
      it from being modified interactively. 
 
 Examples:
 
          CALL PRPAR (5,'NN(,2)','GRP1',0,ADDR,LM,LTOP,MAXD) 
 
     would list the values of NN(1,2), NN(2,2), and NN(3,2) on the logical
      unit 5.
 
     
          CALL PRPAR (5,'NN','GRP1',2,ADDR,LM,LTOP,MAXD) 
 
     copies the contents of parameter NN to  memory starting at the address
      occupied by the variable ADDR. Note that no checks for correct variable
      lengths are performed other than through the MAXD variable. Also MAXD
      must be a variable and not a constant. 
 
 
          CALL PRPAR (5,'NN(2,4)','GRP1',3,JJ,LM,LTOP,MAXD) 
 
     causes the value in JJ to be stored in the parameter location NN(2,4).
 
 
 3.3.8  Encode dimensions into a parameter name
 
 SUBROUTINE ENCN (NAMIN,NAMOUT,NCHR,NDIM,IDIM)
 
     If it is wished to use  variables rather than constants to specify
      dimensions in a parameter name, use this subroutine to form the
      parameter name before using it in  DEFP or PRPAR.
 
     ENCN encodes the first NDIM values in the variable array IDIM and adds
      the string to NAMIN to produce NAMOUT, which can then be used as PNAME
      in the subroutine calls, e.g., the call
 
     CALL ENCN ('INNAME',NAMOUT,NCHR,NDIM,IDIM) 
 
     where NDIM = 3, IDIM(1) = 3, IDIM(2) = 6, IDIM(3) = 4, will result in
      the output of a string array NAMOUT containing 'INNAME (3,6,4)'
 
     A zero value in IDIM will omit the value for that dimension. For
      example, if IDIM(2)  was set to zero in the example, the NAMOUT would
      contain the string 'INNAME (3,,4)'
 
 
 3.3.9  Create new parameter block
 
 SUBROUTINE START (LM,LTOP)
 
     Call this subroutine to initialize a new parameter block, i.e., if you
      wish to create a new parameter file without using GPREC to read in an
      existing parameter block.
 
 
 3.3.10  Convert data between different processor systems
 
     These subroutines are not directly related to accessing parameter data,
 but are included because they may be useful in converting data between the
 different computer system types.
 
 SUBROUTINE RCONV (INTYP,OUTYP,RR,N)
 
     RR is an array containing N floating point (REAL*4) numbers to be
      converted from INTYP to OUTYP. INTYP and OUTYP may have values chosen
      from 1, 2, or 3 as described in Section 3.1.
 
 
 SUBROUTINE ICONV (INTYP,OUTYP,IR,N)
 IR is an array containing N integer (INTEGER*2) numbers to be converted from
 INTYP to OUTYP. INTYP and OUTYP may have values chosen from 1, 2, or 3 as
 described in Section 3.1. The integer formats for type 1 and 2 processors are
 identical.
          
 
 
 3.4  NOTES 
 
   1.	All of the subroutines in  PRMLIB have been compiled with the /4I2
	 switch for Microsoft FORTRAN. This switch causes all integers to be
	 interpreted as INTEGER*2 rather than INTEGER*4 which is the default
	 for the compiler. All integer variable arguments passed to the
	 subroutines must be declared as INTEGER*2. An alternative technique
	 is to compile the calling program also with the switch.
 
   2.	PNAME may contain partial dimensions in order to access a subset of the
	 parameters stored in PNAME, and name and group abbreviations may be
	 used. The program PRM is simply an implementation of the subroutines
	 described in the last section.
 
   3.	If an error condition results, then a message is output to unit LCT. If
	 LCT = 0, then no error messages are generated.
 
 